Toronto Chimney Repair · November 6, 2026
What the rule says now
The requirement sits in Section 2.16 of Division B of the Ontario Fire Code and was expanded by O. Reg. 87/25. According to the TSSA's summary of the change, it applies to all existing homes that have a fuel-burning appliance, a fireplace, an attached garage, or that are heated by air from a fuel-burning appliance outside the home. That covers most detached houses, semis and townhouses in Toronto and the surrounding regions.
Before 2026 the rule only asked for an alarm beside the sleeping areas. Now every storey needs one as well. The City of Toronto's carbon monoxide page lists penalties under the Fire Protection and Prevention Act of up to $50,000 for individuals. Homeowners are responsible in their own homes; in a rental, the landlord installs and maintains the alarms, and Toronto tenants whose alarms are missing can call 311 for a referral to Toronto Fire Services.
Why a wood fireplace counts
Carbon monoxide comes from fuel that burns without enough air. A hot, clean wood fire that draws well sends almost all of it up the flue. Problems start when the fire smoulders or the chimney stops drawing, and then exhaust can spill back into the room.
In older brick houses across the city, the fireplace flue often runs beside a furnace or water heater flue in the same stack. A crack in the masonry between them, or a flue partly blocked by debris, can affect the whole house even if you only light the fireplace a few times a year.
- Wet or unseasoned wood that smoulders instead of burning
- A damper left partly closed, or a fire left to smoulder overnight
- A cap clogged with leaves, or a nest in the flue from the summer
- Kitchen and bathroom fans pulling air down the chimney in a tightly sealed, renovated house
- Broken flue tiles after years of freeze-thaw
Where the alarms go in a typical GTA house
Take a two-storey semi with bedrooms upstairs, a fireplace in the living room and a furnace in the basement. You would want an alarm in the upstairs hallway outside the bedrooms, one on the main floor with the fireplace, and one in the basement near the furnace. If there are bedrooms on two floors, each sleeping area needs its own. Mount each one where the manufacturer's instructions say; combined smoke and carbon monoxide alarms are allowed.
The City of Toronto asks residents to test smoke and carbon monoxide alarms monthly. Ontario's carbon monoxide safety page adds two more habits: replace the batteries every year, and replace the whole alarm when the manufacturer's instructions say to or when it gives its end-of-life warning.
What to do if the alarm goes off
Early carbon monoxide symptoms look like the flu: headache, nausea, dizziness, confusion and drowsiness, as Ontario's guidance lists them. If anyone has symptoms, get everyone out and call 911 from outside. If nobody feels unwell, the City of Toronto suggests checking whether the alarm is signalling a low battery or end of life before calling.
Either way, don't light the fireplace again until the cause is found. With a gas fireplace or furnace, the appliance itself is work for Enbridge Gas or a TSSA-registered gas technician; we handle the chimney side, such as the flue, cap and masonry.
The chimney check that goes with the alarm
The alarm tells you carbon monoxide is in the house; it does not tell you why. Ontario's carbon monoxide safety guidance recommends having fuel-burning appliances, chimneys and vents cleaned and inspected every year before the cold weather sets in, and keeping outside vents and chimneys clear of snow and debris.
Our chimney or fireplace inspection visit is $69 plus HST and is credited toward any repair we do. If the flue needs cleaning, a sweep is $249 to $549 plus HST depending on the build-up, priced before we start. If your insurer wants paperwork for a wood-burning system, a WETT inspection with a written report is $65 plus HST.